Centrale Termica

Case Study

Detail

- n° 1 BNX 2000
- n° 1 ECXV-I 8-12 (tipo A) 800000-1200000 kcal/h - SIXEN 2000 - GX 1200
- n° 1 Pressure transducer for burner modulation BNX-BBNX boilers<=1 bar
- n° 1 Automatic purging " BX 200/1750 - BNX 350/3000" as SINGLE additional accessory

Boilers installed

BNX

Monobloc low-pressure reverse flame wet back steam boiler, suitable for liquid or gaseous fuels., It is a brand-new...

Steam production: 100 ÷ 3000 kg/h

Nominal power: 69,8 ÷ 2035 kW

Design pressure: 0,98 o 0,5 bar

Efficiency: > 91,0 %

GX

The GX range features outstanding monobloc steam generators, designed to give maximum reliability and durability. All models have...

Steam production: 1700 ÷ 32000 kg/h

Nominal power: 1163 ÷ 17442 kW

Design pressure: 12 or 15 bar

Efficiency: 90,0 %

The SIXEN N range consists of monobloc reverse flame wet back fire tube steam boilers. This range is...

Steam production: 350 to 5000 kg / h

Nominal power: 238 ÷ 3407 kW

Design pressure: 12 or 15 bar

Efficiency: > 90.0%