{"id":63115,"date":"2026-04-28T04:01:21","date_gmt":"2026-04-28T03:01:21","guid":{"rendered":"https:\/\/www.icicaldaie.com\/case-study\/%settori%\/aboca-spa\/"},"modified":"2026-04-28T04:01:21","modified_gmt":"2026-04-28T03:01:21","slug":"aboca-spa","status":"publish","type":"case-study","link":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/","title":{"rendered":"Aboca SpA"},"content":{"rendered":"<p> The client required an <strong>autonomous and efficient steam generation system<\/strong> to serve the Research &amp; Development department, which is physically separated from the main steam distribution network.<br \/>\nThe objective was to ensure <strong>operational continuity<\/strong> and <strong>high performance,<\/strong> without the need for constant supervision by certified personnel.<br \/>\n&nbsp;<\/p>\n<h4>Implemented solution<\/h4>\n<p>\nA brand-new <strong>independent boiler room<\/strong> was designed and built, featuring a sandwich panel structure. Inside, a <strong>GSX series steam generator<\/strong> with a capacity of <strong>3 t\/h<\/strong> was installed.<br \/>\nThe plant was equipped with:<\/p>\n<ul>\n<li>A <strong>72H unattended operation system<\/strong><\/li>\n<li>An <strong>economizer <\/strong>for heat recovery<\/li>\n<li><strong>Additional accessories<\/strong> to maximize performance and energy efficiency<\/li>\n<\/ul>\n<h4>\nAchieved results<\/h4>\n<p>\nFollowing close collaboration with the design engineer, the most suitable technical solution was identified: the <strong>GSX 3000 generator,<\/strong> which successfully met all expectations and project requirements by:<\/p>\n<ul>\n<li>Achieving a <strong>thermal efficiency of up to 95%<\/strong><\/li>\n<li>Keeping <strong>NOx emissions below 100 mg\/kWh<\/strong><\/li>\n<li>Ensuring <strong>cost-effective operation<\/strong> without requiring a permanently licensed operator<\/li>\n<\/ul>\n<h4>\nBenefits obtained<\/h4>\n<p>\n&#9989; <strong>Improved energy efficiency<\/strong> from day one<br \/>\n&#9989; <strong>Optimized consumption<\/strong> and lower operating costs<br \/>\n&#9989; <strong>Reduced emissions<\/strong> in compliance with environmental regulations<br \/>\n&#9989; <strong>Certified safety<\/strong> and reduced need for continuous supervision<br \/>\n&nbsp; <\/p>\n","protected":false},"featured_media":73283,"menu_order":1,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"country":[1185],"settori":[1182],"tipo_di_fluido":[1216,1221],"class_list":["post-63115","case-study","type-case-study","status-publish","format-standard","has-post-thumbnail","hentry","country-italy","settori-chemical-and-pharmaceutical","tipo_di_fluido-industrial-boilers","tipo_di_fluido-steam-boilers"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Aboca SpA - ICI<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aboca SpA - ICI\" \/>\n<meta property=\"og:description\" content=\"The client required an autonomous and efficient steam generation system to serve the Research &amp; Development department, which is physically separated from the main steam distribution network. The objective was to ensure operational continuity and high performance, without the need for constant supervision by certified personnel. &nbsp; Implemented solution A brand-new independent boiler room was [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/\" \/>\n<meta property=\"og:site_name\" content=\"ICI\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2025\/05\/Aboca1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1380\" \/>\n\t<meta property=\"og:image:height\" content=\"2448\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/\",\"url\":\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/\",\"name\":\"Aboca SpA - ICI\",\"isPartOf\":{\"@id\":\"https:\/\/www.icicaldaie.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2025\/07\/Aboca4mod.jpg\",\"datePublished\":\"2026-04-28T03:01:21+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#primaryimage\",\"url\":\"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2025\/07\/Aboca4mod.jpg\",\"contentUrl\":\"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2025\/07\/Aboca4mod.jpg\",\"width\":800,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.icicaldaie.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Case Study\",\"item\":\"https:\/\/www.icicaldaie.com\/en\/case-study\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Chemical and Pharmaceutical\",\"item\":\"https:\/\/www.icicaldaie.com\/en\/sectors\/chemical-and-pharmaceutical\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Aboca SpA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.icicaldaie.com\/en\/#website\",\"url\":\"https:\/\/www.icicaldaie.com\/en\/\",\"name\":\"ICI\",\"description\":\"Powering Evolution\",\"publisher\":{\"@id\":\"https:\/\/www.icicaldaie.com\/en\/#organization\"},\"alternateName\":\"ICI Powering Evolution\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.icicaldaie.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.icicaldaie.com\/en\/#organization\",\"name\":\"ICI\",\"url\":\"https:\/\/www.icicaldaie.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.icicaldaie.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2023\/01\/Logo-ICI-Colorato.png\",\"contentUrl\":\"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2023\/01\/Logo-ICI-Colorato.png\",\"width\":450,\"height\":239,\"caption\":\"ICI\"},\"image\":{\"@id\":\"https:\/\/www.icicaldaie.com\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Aboca SpA - ICI","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/","og_locale":"en_US","og_type":"article","og_title":"Aboca SpA - ICI","og_description":"The client required an autonomous and efficient steam generation system to serve the Research &amp; Development department, which is physically separated from the main steam distribution network. The objective was to ensure operational continuity and high performance, without the need for constant supervision by certified personnel. &nbsp; Implemented solution A brand-new independent boiler room was [&hellip;]","og_url":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/","og_site_name":"ICI","og_image":[{"width":1380,"height":2448,"url":"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2025\/05\/Aboca1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/","url":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/","name":"Aboca SpA - ICI","isPartOf":{"@id":"https:\/\/www.icicaldaie.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#primaryimage"},"image":{"@id":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#primaryimage"},"thumbnailUrl":"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2025\/07\/Aboca4mod.jpg","datePublished":"2026-04-28T03:01:21+00:00","breadcrumb":{"@id":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#primaryimage","url":"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2025\/07\/Aboca4mod.jpg","contentUrl":"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2025\/07\/Aboca4mod.jpg","width":800,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/www.icicaldaie.com\/en\/case-study\/chemical-and-pharmaceutical\/aboca-spa\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.icicaldaie.com\/en\/"},{"@type":"ListItem","position":2,"name":"Case Study","item":"https:\/\/www.icicaldaie.com\/en\/case-study\/"},{"@type":"ListItem","position":3,"name":"Chemical and Pharmaceutical","item":"https:\/\/www.icicaldaie.com\/en\/sectors\/chemical-and-pharmaceutical\/"},{"@type":"ListItem","position":4,"name":"Aboca SpA"}]},{"@type":"WebSite","@id":"https:\/\/www.icicaldaie.com\/en\/#website","url":"https:\/\/www.icicaldaie.com\/en\/","name":"ICI","description":"Powering Evolution","publisher":{"@id":"https:\/\/www.icicaldaie.com\/en\/#organization"},"alternateName":"ICI Powering Evolution","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.icicaldaie.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.icicaldaie.com\/en\/#organization","name":"ICI","url":"https:\/\/www.icicaldaie.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.icicaldaie.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2023\/01\/Logo-ICI-Colorato.png","contentUrl":"https:\/\/www.icicaldaie.com\/wp-content\/uploads\/2023\/01\/Logo-ICI-Colorato.png","width":450,"height":239,"caption":"ICI"},"image":{"@id":"https:\/\/www.icicaldaie.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.icicaldaie.com\/en\/wp-json\/wp\/v2\/case-study\/63115","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.icicaldaie.com\/en\/wp-json\/wp\/v2\/case-study"}],"about":[{"href":"https:\/\/www.icicaldaie.com\/en\/wp-json\/wp\/v2\/types\/case-study"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.icicaldaie.com\/en\/wp-json\/wp\/v2\/media\/73283"}],"wp:attachment":[{"href":"https:\/\/www.icicaldaie.com\/en\/wp-json\/wp\/v2\/media?parent=63115"}],"wp:term":[{"taxonomy":"country","embeddable":true,"href":"https:\/\/www.icicaldaie.com\/en\/wp-json\/wp\/v2\/country?post=63115"},{"taxonomy":"settori","embeddable":true,"href":"https:\/\/www.icicaldaie.com\/en\/wp-json\/wp\/v2\/settori?post=63115"},{"taxonomy":"tipo_di_fluido","embeddable":true,"href":"https:\/\/www.icicaldaie.com\/en\/wp-json\/wp\/v2\/tipo_di_fluido?post=63115"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}